ASA Analytics
  • Home
  • Applications
    • Municipal Water Monitoring >
      • Ammonia Feed
      • Chloramination Control
      • Chlorination
      • Color Analysis
      • Distribution Monitoring
      • Hardness Monitoring
      • Ion Exchange Breakthrough
      • Natural Organic Matter (NOM) Removal
      • Peak Point Chloramination Control
      • Phosphate Sequesterant Feed Control
      • Reservoir Monitoring
      • Security Monitoring
      • TOC Monitoring
      • Well Blending
    • Wastewater Monitoring and Control >
      • Aeration Control and Energy Cost Reduction
      • Biological Nutrient Removal
      • Biological Phosphorus Removal
      • Chemical Phosphorus Removal
      • Chloramination /Breakpoint Avoidance
      • Chlorination/De-Chlorination
      • De-Nitrification Monitoring
      • Nitrification
      • Nutrient Deficiency Analysis
      • Lagoon Discharge
      • SBR Stage Control
      • TOC Monitoring
      • UV Disinfection Control
    • Industrial Water Treatment >
      • Boiler Water Analysis
      • Cooling Water Analysis (Closed Loop)
    • Industrial Process Monitoring >
      • Electroless Plating
    • ASA Technical Papers (ALL)
    • ChemScan Installation Photos
  • Service
    • Contact Service
    • ChemScan Service Team
    • MSDS
    • Communication Protocols
    • Software Utilities
    • Service Videos
  • Parts
  • Company
    • Terms and Conditions
    • Contact Form (General Inquiry)
    • Contact Service
    • Application Data Sheet
    • Employment Opportunities
    • Representatives and Distributors
  • Products
    • ChemScan Mini Analyzer >
      • mini oP (Ortho Phosphate)
      • mini oP (Ortho Phosphate) Extended Range
      • mini LoP (Low Ortho Phosphate)
      • mini UV-254
      • mini LowAm (Low Ammonia)
      • mini Mn (Manganese)
      • mini LowChlor (Low Chlorine)
      • mini Sulfite
      • mini Mono (Monochloramine)
      • mini FreeAm (Free Ammonia)
      • mini Cu (Copper)
      • mini CrVI
      • mini Low CrVI
      • mini Fe (Iron)
      • mini Ni (Nickel)
      • mini Silica
    • ChemScan mini Accessories
    • ChemScan Process Analyzers >
      • ChemScan 2150/S Chloramination Analyzer
      • ChemScan 2150/DC Chem Feed Analyzer
      • ChemScan 2150/N Aeration Rate Analyzer
      • ChemScan 2150/NoP Chem Feed Analyzer
      • ChemScan 2150/NHoP Nutrient Analyzer
      • ChemScan 2150 Process Analyzer
      • ChemScan UV-3150 Process Analyzer
      • ChemScan 4100 Nutrient Control
      • ChemScan 6101 Nutrient Control
    • ChemScan Alkalinity Analyzer >
      • For Wastewater
      • For Water
    • ChemScan Accessories

ChemScan mini Mn (Manganese Analyzer)

​For Real-Time Wastewater Analysis

Picture
​

Picture
Picture
Picture
Picture
mini oP Demo Video
mini oP Installation

ChemScan mini Mn Documents

mini-manganese-analyzer-large.jpg
File Size: 2429 kb
File Type: jpg
Download File

mini Manganese Brochure
File Size: 219 kb
File Type: pdf
Download File

mini Mn Technical Specs 2 Reagents (1063)
File Size: 137 kb
File Type: pdf
Download File

mini Mn Technical Specs 3 Reagents (1064)
File Size: 138 kb
File Type: pdf
Download File

mini Mn Installation Diagram
File Size: 67 kb
File Type: pdf
Download File

mini Piping Diagram
File Size: 25 kb
File Type: pdf
Download File

min Mn Procurement Specs.
File Size: 97 kb
File Type: pdf
Download File

ChemScan mini Sample O&M Manual
File Size: 1641 kb
File Type: pdf
Download File

Sample Extraction System
File Size: 63 kb
File Type: pdf
Download File

ChemScan mini full Catalog
File Size: 1332 kb
File Type: pdf
Download File

​The single parameter in-line analyzer family from ASA Analytics utilizes years of ChemScan® experience and proven technology to provide reliable and accurate analysis of water and waste water. This device has been designed from the ground up to reduce maintenance requirements, includes large ID sample tubing to minimize plugging and only needs quarterly reagent refills.
Benefits
  • High Reliability
  • Low Capital Cost
  • High Accuracy
  • Low Operating Cost

Applications
  • Potable Water
  • Waste Water Effluent 

Features
  • Automatic Analysis Utilizing
    Proven Formaldoxime Method
  • Low Maintenance
  • Proven Sample Handling with Large I.D. Flow Paths
  • Simple Field Adjustable Calibration
  • Sample Blank to Eliminate Backgound Interference
  • Automatic Cleaning

Capabilities
  • Automatic Analysis
  • Continuous Output
  • Multiple Data Communication Interface Options

​Parameter
  • Manganese
Specifications:

Range:

0.02 - 8.0 mg/L (Method #1063, #1064)

Accuracy:
2% of value or 2x detection limit (whichever greater)

Cycle Time:
15 minutes (1064) 10 min (1063) to 9999 minutes (field programmable)

Environment:
5 - 50 degrees C (method dependent)

Power:
100 - 240 VAC, 50 W

Enclosure:
NEMA 4x

Safety Approval:
CSA-US

Sample Requirements:
0.5 - 1 Liter/analysis, pressure 2 to 10 psi,
<150 mg/L TSS, <60 NTU

Maintenance:
Reagent replacement every 3 months, pump kit yearly

Relay Contacts:
1 SPDT Concentration, 1 SPDT Programmable

Serial Interface:
RS-232 Maintenance Port

​Analog Output:
Isolated 4-20 mA
Applied Spectrometry Associates, Inc.
2325 Parklawn Dr., Suite I, Waukesha, WI 53186
​Phone: 262-717-9500
Toll Free: 800-665-7133

Contact Us

  • Home
  • Applications
    • Municipal Water Monitoring >
      • Ammonia Feed
      • Chloramination Control
      • Chlorination
      • Color Analysis
      • Distribution Monitoring
      • Hardness Monitoring
      • Ion Exchange Breakthrough
      • Natural Organic Matter (NOM) Removal
      • Peak Point Chloramination Control
      • Phosphate Sequesterant Feed Control
      • Reservoir Monitoring
      • Security Monitoring
      • TOC Monitoring
      • Well Blending
    • Wastewater Monitoring and Control >
      • Aeration Control and Energy Cost Reduction
      • Biological Nutrient Removal
      • Biological Phosphorus Removal
      • Chemical Phosphorus Removal
      • Chloramination /Breakpoint Avoidance
      • Chlorination/De-Chlorination
      • De-Nitrification Monitoring
      • Nitrification
      • Nutrient Deficiency Analysis
      • Lagoon Discharge
      • SBR Stage Control
      • TOC Monitoring
      • UV Disinfection Control
    • Industrial Water Treatment >
      • Boiler Water Analysis
      • Cooling Water Analysis (Closed Loop)
    • Industrial Process Monitoring >
      • Electroless Plating
    • ASA Technical Papers (ALL)
    • ChemScan Installation Photos
  • Service
    • Contact Service
    • ChemScan Service Team
    • MSDS
    • Communication Protocols
    • Software Utilities
    • Service Videos
  • Parts
  • Company
    • Terms and Conditions
    • Contact Form (General Inquiry)
    • Contact Service
    • Application Data Sheet
    • Employment Opportunities
    • Representatives and Distributors
  • Products
    • ChemScan Mini Analyzer >
      • mini oP (Ortho Phosphate)
      • mini oP (Ortho Phosphate) Extended Range
      • mini LoP (Low Ortho Phosphate)
      • mini UV-254
      • mini LowAm (Low Ammonia)
      • mini Mn (Manganese)
      • mini LowChlor (Low Chlorine)
      • mini Sulfite
      • mini Mono (Monochloramine)
      • mini FreeAm (Free Ammonia)
      • mini Cu (Copper)
      • mini CrVI
      • mini Low CrVI
      • mini Fe (Iron)
      • mini Ni (Nickel)
      • mini Silica
    • ChemScan mini Accessories
    • ChemScan Process Analyzers >
      • ChemScan 2150/S Chloramination Analyzer
      • ChemScan 2150/DC Chem Feed Analyzer
      • ChemScan 2150/N Aeration Rate Analyzer
      • ChemScan 2150/NoP Chem Feed Analyzer
      • ChemScan 2150/NHoP Nutrient Analyzer
      • ChemScan 2150 Process Analyzer
      • ChemScan UV-3150 Process Analyzer
      • ChemScan 4100 Nutrient Control
      • ChemScan 6101 Nutrient Control
    • ChemScan Alkalinity Analyzer >
      • For Wastewater
      • For Water
    • ChemScan Accessories